Complete Help Docs

Laser Show Technology for Lighting Professionals

User Tools

Site Tools


accessories:beam-analyzer-c100

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
accessories:beam-analyzer-c100 [2024/04/30 14:55]
Bob Varkevisser
accessories:beam-analyzer-c100 [2024/12/28 13:07] (current)
Bob Varkevisser [Download and installation of the software]
Line 8: Line 8:
  
 ====== Technical Specifications ====== ====== Technical Specifications ======
 +
 +=== Optical ===
 +|< 100% 60% ^ 40% >|
 +^ Parameter ^ Range ^
 +| Optical power (*) (* *) | 0.1W - 100W | 
 +| Accuracy on power measurement (Calibrated on 635nm / 520nm / 445nm). Other wavelengths can be added by the user | 1% |
 +| Resolution on divergence (by design) | 0.01 mrad |
 +| Typical accuracy (+/-) | 0.01 mrad |
 +| Divergence measured (FWHM) | 0.1 mrad - 10 mrad |
 +| Input beam diameter | 22mm |
 +| Wavelength detected | 400nm - 1000nm |
 +
 +(*) The case of the LBA-C must remain below 55°C while operating. It may be needed to dissipate heat from the case with a fan when using the device with high-power beams for a long period.
 +
 +(* *) A correct alignment should be done before setting the laser projector to maximum power. The user must follow the alignment procedure described in the User Manual to prevent damage to the system.
 +
 +=== Mechanical ===
 +|< 100% 60% ^ 40% >|
 +^ Parameter ^ Value ^
 +| Length x Width x Height (mm) (Without holder) | 105 x 75 x 59 |
 +| Length x Width x Height (mm) (With holder) | 153 x 110 x 70 |
 +| Weight ( Without holder ) | 600g |
 +| Weight ( With holder ) | 800g |
 +
 +=== Electrical ===
 +|< 100% 60% ^ 40% >|
 +^ Parameter ^ Value ^
 +| Typical Power consumption (USB 3.0) | 2W |
  
  
Line 16: Line 44:
  
   * USB 3.0 port   * USB 3.0 port
-  * Computer with Windows 10 or 11 installed+  * Computer with Windows 10 or higher
  
 ====== How to use the Beam Analyzer ====== ====== How to use the Beam Analyzer ======
Line 24: Line 52:
 To install the software, simply download and start the setup file “LBA_vX.XX_setup.exe” (X.XX is the version of the software). The latest version of the software can be found **[[https://lightdiction.com/en/Downloads#lba|here]]**. To install the software, simply download and start the setup file “LBA_vX.XX_setup.exe” (X.XX is the version of the software). The latest version of the software can be found **[[https://lightdiction.com/en/Downloads#lba|here]]**.
  
 +[[https://download.pangolin.com/_Files/pointCue-for-beam-analyzer.bcue|Here you can download the testframe for BEYOND.]]
 ==== Shoot the laser beam on the beam analyzer ==== ==== Shoot the laser beam on the beam analyzer ====
  
 {{:accessories:beam-analyzer-lba-c-100-2.png?nolink}} {{:accessories:beam-analyzer-lba-c-100-2.png?nolink}}
 +
  
 Place the LBA-C-100 in front of the laser output to measure, as shown in the following picture. Use the holder to adjust the height if necessary. Place the LBA-C-100 in front of the laser output to measure, as shown in the following picture. Use the holder to adjust the height if necessary.
Line 34: Line 64:
 Start your “Beam Analyzer” software. Select the LBA-C-100 sensor from the list, then start Streaming. Start your “Beam Analyzer” software. Select the LBA-C-100 sensor from the list, then start Streaming.
  
-{{:accessories:beam-analyzer-lba-c-100-3.png?nolink}}+{{accessories:beam-analyzer-lba-c-100-3.png?nolink}}
  
-The sensor should remain below 75°C at any time.+__**The sensor should remain below 75°C at any time.**__
  
 Create a beam pattern, with around 1000 points (~30FPS), or the maximum point number you can if 1000 is not possible, set it to low power and enable it. Incline slightly Left, right, Up, and down the LBA-C-100 in front of your laser until you see a part of the “9 spots pattern”. Keep shooting at the center of the lens. Create a beam pattern, with around 1000 points (~30FPS), or the maximum point number you can if 1000 is not possible, set it to low power and enable it. Incline slightly Left, right, Up, and down the LBA-C-100 in front of your laser until you see a part of the “9 spots pattern”. Keep shooting at the center of the lens.
accessories/beam-analyzer-c100.1714481736.txt · Last modified: 2024/04/30 14:55 by Bob Varkevisser