Complete Help Docs

Laser Show Technology for Lighting Professionals

User Tools

Site Tools


accessories:beam-analyzer-c100

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
accessories:beam-analyzer-c100 [2024/04/30 15:17]
Bob Varkevisser [Requirements]
accessories:beam-analyzer-c100 [2024/12/28 13:07] (current)
Bob Varkevisser [Download and installation of the software]
Line 10: Line 10:
  
 === Optical === === Optical ===
 +|< 100% 60% ^ 40% >|
 ^ Parameter ^ Range ^ ^ Parameter ^ Range ^
 | Optical power (*) (* *) | 0.1W - 100W |  | Optical power (*) (* *) | 0.1W - 100W | 
-| Accuracy on power measurement (Calibrated on RGB) | 1% |+| Accuracy on power measurement (Calibrated on 635nm / 520nm / 445nm). Other wavelengths can be added by the user | 1% |
 | Resolution on divergence (by design) | 0.01 mrad | | Resolution on divergence (by design) | 0.01 mrad |
 | Typical accuracy (+/-) | 0.01 mrad | | Typical accuracy (+/-) | 0.01 mrad |
Line 24: Line 25:
  
 === Mechanical === === Mechanical ===
-^ Parameter ^ ^ +|< 100% 60% ^ 40% >| 
 +^ Parameter ^ Value ^
 | Length x Width x Height (mm) (Without holder) | 105 x 75 x 59 | | Length x Width x Height (mm) (Without holder) | 105 x 75 x 59 |
 | Length x Width x Height (mm) (With holder) | 153 x 110 x 70 | | Length x Width x Height (mm) (With holder) | 153 x 110 x 70 |
-| Weight – With holder | 600g | +| Weight ( Without holder | 600g | 
-| Weight – With holder | 800g |+| Weight With holder | 800g |
  
 === Electrical === === Electrical ===
-^ Parameter ^ ^ +|< 100% 60% ^ 40% >| 
 +^ Parameter ^ Value ^
 | Typical Power consumption (USB 3.0) | 2W | | Typical Power consumption (USB 3.0) | 2W |
  
Line 49: Line 52:
 To install the software, simply download and start the setup file “LBA_vX.XX_setup.exe” (X.XX is the version of the software). The latest version of the software can be found **[[https://lightdiction.com/en/Downloads#lba|here]]**. To install the software, simply download and start the setup file “LBA_vX.XX_setup.exe” (X.XX is the version of the software). The latest version of the software can be found **[[https://lightdiction.com/en/Downloads#lba|here]]**.
  
 +[[https://download.pangolin.com/_Files/pointCue-for-beam-analyzer.bcue|Here you can download the testframe for BEYOND.]]
 ==== Shoot the laser beam on the beam analyzer ==== ==== Shoot the laser beam on the beam analyzer ====
  
Line 62: Line 66:
 {{accessories:beam-analyzer-lba-c-100-3.png?nolink}} {{accessories:beam-analyzer-lba-c-100-3.png?nolink}}
  
-The sensor should remain below 75°C at any time.+__**The sensor should remain below 75°C at any time.**__
  
 Create a beam pattern, with around 1000 points (~30FPS), or the maximum point number you can if 1000 is not possible, set it to low power and enable it. Incline slightly Left, right, Up, and down the LBA-C-100 in front of your laser until you see a part of the “9 spots pattern”. Keep shooting at the center of the lens. Create a beam pattern, with around 1000 points (~30FPS), or the maximum point number you can if 1000 is not possible, set it to low power and enable it. Incline slightly Left, right, Up, and down the LBA-C-100 in front of your laser until you see a part of the “9 spots pattern”. Keep shooting at the center of the lens.
accessories/beam-analyzer-c100.1714483059.txt · Last modified: 2024/04/30 15:17 by Bob Varkevisser