 ====== Technical Specifications ====== ====== Technical Specifications ======
 +
 +=== Optical ===
 +|< 100% 60% ^ 40% >|
 +^ Parameter ^ Range ^
 +| Optical power (*) (* *) | 0.1W - 100W | 
 +| Accuracy on power measurement (Calibrated on RGB) | 1% |
 +| Resolution on divergence (by design) | 0.01 mrad |
 +| Typical accuracy (+/-) | 0.01 mrad |
 +| Divergence measured (FWHM) | 0.1 mrad - 10 mrad |
 +| Input beam diameter | 22mm |
 +| Wavelength detected | 400nm - 1000nm |
 +
 +(*) The case of the LBA-C must remain below 55°C while operating. It may be needed to dissipate heat from the case with a fan when using the device with high-power beams for a long period.
 +
 +(* *) A correct alignment should be done before setting the laser projector to maximum power. The user must follow the alignment procedure described in the User Manual to prevent damage to the system.
 +
 +=== Mechanical ===
 +|< 100% 60% ^ 40% >|
 +^ Parameter ^ Value ^
 +| Length x Width x Height (mm) (Without holder) | 105 x 75 x 59 |
 +| Length x Width x Height (mm) (With holder) | 153 x 110 x 70 |
 +| Weight ( Without holder ) | 600g |
 +| Weight ( With holder ) | 800g |
 +
 +=== Electrical ===
 +|< 100% 60% ^ 40% >|
 +^ Parameter ^ Value ^
 +| Typical Power consumption (USB 3.0) | 2W |
  
  
Line 16: Line 44:
  
   * USB 3.0 port   * USB 3.0 port
-  * Computer with Windows 10 or 11 installed+  * Computer with Windows 10 or higher
  
 ====== How to use the Beam Analyzer ====== ====== How to use the Beam Analyzer ======
Line 37: Line 65:
 {{accessories:beam-analyzer-lba-c-100-3.png?nolink}} {{accessories:beam-analyzer-lba-c-100-3.png?nolink}}
  
-The sensor should remain below 75°C at any time.+__**The sensor should remain below 75°C at any time.**__
  
 Create a beam pattern, with around 1000 points (~30FPS), or the maximum point number you can if 1000 is not possible, set it to low power and enable it. Incline slightly Left, right, Up, and down the LBA-C-100 in front of your laser until you see a part of the “9 spots pattern”. Keep shooting at the center of the lens. Create a beam pattern, with around 1000 points (~30FPS), or the maximum point number you can if 1000 is not possible, set it to low power and enable it. Incline slightly Left, right, Up, and down the LBA-C-100 in front of your laser until you see a part of the “9 spots pattern”. Keep shooting at the center of the lens.