beyond:40_-lasers [2025/05/09 09:40] Bob Varkevisser [Check out more about performance:] |
beyond:40_-lasers [2025/05/09 19:23] (current) Bob Varkevisser [For Timeline shows:] |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== 40+ lasers ====== | ====== 40+ lasers ====== | ||
- | BEYOND Ultimate currently | + | BEYOND Ultimate currently supports 40 Hardware controllers (FB4 or FB3) per installation. This requires a high-performance pc to run. However, there are a few options, as we do have a number of clients who regularly exceed 40 lasers, and even up to hundreds of lasers. This mainly looks like having multiple PCs running together. |
===== For Timeline shows: ===== | ===== For Timeline shows: ===== | ||
Line 9: | Line 9: | ||
Once you are finished programming, | Once you are finished programming, | ||
- | The easiest to code them all together | + | Probably the easiest |
- | Otherwise, you will want to have something like a TC4000 for each computer and run separate audio tracks to each. | + | You can broadcast Artnet timecode on a network that is separate from all the laser nets by plugging each pc into this separate network through additional network adapters on those computers. Then some master can send it all over the network, and all BEYOND instances can listen to it. |
+ | |||
+ | Otherwise, you may use a TC4000 | ||
We recommend maintaining a PC as the " | We recommend maintaining a PC as the " |