This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
tools:lcflash:scan_speeds_and_lc_flash [2021/04/23 12:40] Bob Varkevisser created |
tools:lcflash:scan_speeds_and_lc_flash [2021/05/02 23:47] (current) Bob Varkevisser |
||
---|---|---|---|
Line 12: | Line 12: | ||
The ILDA 30K tuning standard says that your scanners can show the ILDA Test Pattern in a specific way (circle touching the sides of the square), when the ILDA Test Pattern is displayed at 30,000 points per second: | The ILDA 30K tuning standard says that your scanners can show the ILDA Test Pattern in a specific way (circle touching the sides of the square), when the ILDA Test Pattern is displayed at 30,000 points per second: | ||
- | | img | img | img | | + | | {{: |
| Scanning too slow: \\ Circle outside of square | Scanning too fast: \\ Circle can't touch square | Scanning correctly: \\ Circle touches midpoint of square | | | Scanning too slow: \\ Circle outside of square | Scanning too fast: \\ Circle can't touch square | Scanning correctly: \\ Circle touches midpoint of square | | ||
Line 37: | Line 37: | ||
===== Better scanners give better results ===== | ===== Better scanners give better results ===== | ||
- | Lasershow Converter FLASH gives the best results if your scanners are tuned perfectly, and the bearings are in good shape. Please make sure that the low frequency damping and high frequency damping are adjusted properly for " | + | Lasershow Converter FLASH gives the best results if your scanners are tuned perfectly, and the bearings are in good shape. Please make sure that the low frequency damping and high frequency damping are adjusted properly for " |
+ | ---- | ||
+ | [[tools: |